-Control activation: control. activates through water conductivity with a reading wait of 30 seconds.
-Control deactivation: control deactivates when the ice covers the probe, with a forced stopped of 20 minutes (AL.901) and 62 minutes (AL.908) by means of a microprocessor predeterminate for this control.
-Checking at the stop cycle: it can be checked during the stop cycle if the ice-thickness control is activated just by desconnecting the beer cooler and connecting it again. The cycle goes to 0 and it will give us a reading 30 seconds after we connect the machine again. If the reading of the microprocessor corresponds to water among the terminals of the probe, it will go on until it finds some ice. If, on the contrary, when doing the reading, it detects some ice, the cooler will stop after 30 seconds as a normal cycle.
-Control starter: pitting the probe, instant starter.
-Control stop: unpitting the probe, instant stop.
-In this operation no cycle of forced stopping is activated. |